HVAC School - For Techs, By Techs
HVAC School - For Techs, By Techs
Bryan Orr
Real training for HVAC ( Heating, Ventilation, Air Conditioning and Refrigeration) Technicians. Including recorded tech training, interviews, diagnostics and general conversations about the trade.
Dew You Get the Point — Tim De Stasio and Sophie Ashley
Relative humidity is the number most technicians and homeowners know, but it can mislead. In this symposium session, Tim De Stasio and Sophie Ashley make the case that HVAC professionals should think in terms of dew point, an absolute measure of how much moisture is actually in the air. Using a glass-of-water analogy and the psychrometric chart, they show why 50% relative humidity means very different things in warm and cool air, and why air leaving an evaporator coil can read 100% RH while being far drier than the air that entered. From there, Tim turns dew point into practical field tools. He sets a summer indoor target of 75°F dry bulb and a 55°F dew point, then shows how to screen a system with two psychrometers: dew point should match between the return grille and the return plenum (a mismatch signals return leakage), and supply dew point should be lower than return dew point and within about three degrees of supply dry bulb. He also explains why the hottest day is rarely the most humid, which makes the case for supplemental dehumidification, and walks through the idea that condensation is simply high dew point air meeting a cooler surface. Sophie brings the building science view, with data logger charts from her own home in South Carolina, a tiny house in California, and her encapsulated attic. She shows how dew point exposed a winter window condensation problem and a daily "ping-pong" moisture cycle in open-cell foam at the roof deck, and how a ventilating dehumidifier and a conditioned attic supply fixed it. Her message is that dew point lets you find problems you would never see in relative humidity, and confirm that your fixes worked. The session closes with an extended Q&A covering how to measure dew point in attics, attic dew point differences, vapor diffusion ports, sealing supply boots from the attic side, and a stubborn case of sweating ductwork in a two-story home's floor cavity. Topics Covered Relative versus absolute humidity, and why relative humidity alone "lies" Reading dew point on the psychrometric chart and in the MeasureQuick app Saturation, evaporator coil dehumidification, and why supply air can read 100% RH Summer design targets: 75°F dry bulb and 55°F dew point, plus Tim's "60 rule" Outdoor design conditions, peak dehumidification days, and oversized equipment on mild humid days Return duct leak screening using dew point at the grille versus the plenum Evaporator performance checks: supply dew point below return, within about 3°F of dry bulb Why inverter and variable-capacity systems can struggle with humidity at part load Condensation diagnosis: lower the dew point of the air or raise the surface temperature Register sweat, bathroom ceiling condensation, and sweating ducts in crawl spaces and attics Winter window condensation, ventilating dehumidifiers, ERVs, and register placement Vented versus encapsulated attics, knee wall air barriers, and the ping-pong effect Vapor diffusion ports as a supplement to, not a substitute for, dehumidification Data logging with HAVEN and other loggers to track indoor and outdoor dew point This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, Fieldpiece, and the 2027 AHR Expo. Resources A House Needs to Breathe... Or Does It? (Dr. Allison Bailes's book) Condensation Control Calculator for Horizontal Pipe (insulation.org calculator) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 26
1 hr 25 min
It Lit. That Doesn't Mean You're Done - Short #313
In this short podcast episode, Bryan talks about why you're not done with a furnace service call or installation just because it lit. Ignition is just one part of the furnace sequence of operations, and the furnace still needs to deliver heat and vent flue gases safely. The key takeaway here is that if we only focus on making sure "it lit," we could miss overfiring, poor air delivery, intermittent limit problems, or venting problems. We want to be able to observe the complete sequence of operations. What happens when the blower starts is useful information, as is what happens when it's been running for several minutes. Fuel input also matters. The furnace nameplate tells you which fuel type a system is designed for, as well as the gas pressure readings and the temperature rise. The BTU value of the fuel also matters, which you can determine by clocking the gas meter, and then our temperature and pressure corrections will also be important factors. When commissioning a gas furnace, we should measure gas pressure and temperature rise (the increase between return air entering the furnace and the supply air leaving it), perform combustion analysis, and wear a low-level personal CO monitor. We can also verify airflow with a TrueFlow grid. We should also NOT bypass safeties at any point; we should check any safeties with a meter and investigate why they're behaving a certain way. Temperature rise and airflow problems may also point us toward some common issues, including easily fixed ones like dirty filters and systemic issues like poor ductwork. Other things to watch include shutdown, condensate removal (for high-efficiency furnaces), burner alignment, all flue assemblies (visual inspection, termination points, and monitoring CO spillage), and the likelihood of depressurization. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, Fieldpiece,  and Filtrete. Resources Furnace Commissioning Part 1 w/ Jim Bergmann - Input / Rise (podcast) Furnace Commissioning Part 2 w/ Jim Bergmann (podcast) Combustion Analysis w/ Jim Bergmann (podcast) Clocking a Gas Meter (It's Not That Hard) (tech tip) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 24
13 min
HVAC Troubleshooting 101 w/ Jim Fultz
In this session from the 2026 HVACR Training Symposium, Jim Fultz walks through his HVAC 101 class to help techs get through any gas furnace call. Jim's core message is to start with your senses, not your meter. Look, listen, smell, and ask the homeowner what they experienced before touching a tool, then use instruments to confirm what your observations suggest. An 80% furnace has a short list of components and a clear sequence of operations: call for heat, limit and pressure switch checks, inducer start, igniter warm-up, gas valve opening, flame proving, and the timed blower. When a furnace stops partway through that sequence, the stopping point tells you where to look. Jim also encourages techs to cycle a repaired furnace two or three times so they memorize what normal looks like, the way a bank teller learns real currency to spot counterfeits. From there, Jim goes component by component, mixing practical tests with field stories. Topics include hot surface igniters, PSC and constant torque blower motors, capacitors, flame sensing, gas valves, pressure switches, and thermostat wiring. Along the way, he shares lessons such as checking amp draw even after a capacitor swap, measuring DC as well as AC on modern blower signals, and never assuming a wire's color is consistent from end to end. He also explains why wiring works as pairs, which makes board replacement far easier. Jim closes with a look at truck stock and time management, pointing out that every parts run costs a billable hour. He also covers some White-Rodgers resources, including the mobile cross-reference app, universal controls, and private-label thermostats. Topics Covered Developing a troubleshooting thought process: observe first, measure second Using the board LED, thermostat batteries, and float switches as quick first checks Recreating the homeowner's complaint and listening to what customers report Sequence of operation for an 80% furnace, including typical timings (15-second pre-purge, 17-second warm-up for 120V igniters, 5-second flame proving) High-voltage versus low-voltage circuits, and why almost every component is wired in pairs Tracing circuits on wiring diagrams one circuit at a time Voltage versus continuity versus amperage: when to use each Tracking down blown low-voltage fuses, from DIY thermostat installs to rubbed wires Hot surface igniters: silicon carbide versus silicon nitride, cracks, and handling PSC blowers, capacitor tolerances, and checking amp draw after a replacement Constant torque (ECM X13) motors and the shift to DC control signals Flame rectification: how it works, microamp readings, and cleaning the flame rod without sandpaper Grounding problems, including a furnace that quit after a panel upgrade Gas valves: DC coils, why you can't ohm them, and checking inlet gas first Pressure switch testing tips and thermostat wire continuity checks Truck stock strategy, universal controls, and the cost of parts runs The key takeaway from this session is to pay attention to where the actual sequence of operations differs from the expected sequence. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Copeland, Santa Fe Dehumidifiers, and TruTech Tools. Resources White-Rodgers by Copeland (website) Copeland's mobile apps (including Copeland Mobile, White-Rodgers Connect, and Sensi) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 19
1 hr 8 min
Why Every HVAC Company Needs a Home Performance Contractor - Short #312
In this short podcast episode, Bryan explains why every HVAC company needs a home performance contractor (or at least access to the skills provided by home performance contractors). Many people try to solve comfort issues by upsizing the equipment or changing fan settings, but there could be several building- or duct-related issues at play. We start with complaints we can investigate, including discomfort in certain rooms or the presence of moisture or growth. Then, we can establish what the HVAC system is delivering with temperature, pressure, and electrical readings. Our senses can tell us if something might be wrong with the filter or the duct system. We can also use tools like the TrueFlow grid to measure airflow, but those don't necessarily tell us how air moves throughout a home, such as if there is an inadequate return path or if there are pressure imbalances between rooms. We can investigate those pressure imbalances with precision manometers, correct the complaint by adding or improving a return path, and test out after a solution has been implemented. Supply ducts often leak into vented attics, which can cause attic air to enter the home and bring moisture with it. Return leaks can draw moist air directly into the return airstream, too. Again, we can test in, make a repair, and test out to improve those comfort and air quality problems.  Upsizing equipment as a response to comfort complaints can bring other issues. Rooms may be cold but clammy since short runtimes don't allow the coil to get cold enough for long enough to remove humidity effectively. Ultimately, we have to understand the entire system and the surrounding conditions (including dew point) when considering comfort solutions. If your company does not have the means to do home performance testing, you and your customers may benefit from forming good relationships with contractors who offer home performance testing and solutions. Those contractors can also bring your business some leads in return. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Fieldpiece, TruTech Tools, and Filtrete. Resources Mike Cianfrocco's Bry-X session (accessible with a virtual symposium ticket) An IAQ & Dehum Case Study w/ Genry and Nikki (podcast) Solving Comfort and IAQ Issues in a Vintage Home: A Case Study (tech tip) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 17
12 min
Deliver High Performance Heat Pump Retrofits w/ David Richardson
Heat pumps may be everywhere, but according to David Richardson, the industry is in danger of aiming at the wrong target. In this 2026 HVACR Training Symposium session, the Kentucky contractor's son, who has never lived in a home without a heat pump, opens with the story of Olympic rifle shooter Matthew Emmons. Emmons hit the bullseye with perfect precision in 2004, only to discover he had fired at the wrong lane's target. Richardson argues that contractors risk the same mistake when they treat the heat pump itself as the goal and market it with the same "magic" promises used in the 1970s, a pattern that led to poor installations and a reputation problem that has lasted 50 years. The real target, Richardson says, is the customer, and the heat pump is only one ring on that target alongside ductwork, the building envelope, equipment sizing, noise, and expectations. He distinguishes between HVAC equipment, which anyone can sell, and the HVAC system, which is where a contractor's skill and craftsmanship show up. Average installations, he notes, deliver roughly 57% of rated performance, while a high-performance retrofit aims for 88% or better. With "free heat pump" offers likely coming next, he urges contractors to differentiate through engagement, education, clear expectations, and measured results, ending with what he calls a "craftsmanship receipt." The heart of the talk is five practical tips. First, learn what the customer is really after and set expectations early, including what a defrost cycle looks like. Second, don't inherit a bad duct system, and use pressure, airflow, and temperature measurements to find problems before they become yours. Third, don't inherit a bad building, since the structure works like a duct system and can undermine a perfect install. Fourth, bring the customer along by putting simple tools in their hands, such as a thermal camera or flow hood, and translating data into plain language. Fifth, follow a repeatable process that defines where testing begins and where additional paid services start. Richardson closes with a call to document lessons learned, including mistakes, and to build these practices into company culture. His message is that heat pumps aren't magic, but they can perform as if they were when installed well and priced to reflect the work. The session wraps with audience questions. Topics Covered The Olympic shooter analogy: precision aimed at the wrong target History of heat pumps, the 1970s energy crisis, and early marketing hype Why heat pumps shouldn't be treated as a silver bullet, and the "silver buckshot" approach HVAC equipment versus the HVAC system Installation performance benchmarks: roughly 57% for average work, about 6% more for code-approved work, and a goal of 88% or better The three E's: engagement, education, and expectations, plus measured results The craftsmanship receipt and verification: "if you don't test, you're just guessing" Setting customer expectations, including cold-climate performance and defrost Right-sizing and the pitfalls of oversized equipment, even with inverter technology Testing for pressure, airflow, and temperature (PAT) and not inheriting bad ductwork Building science basics: leakage, room pressures, blower doors, and thermal imaging Using Socratic questions and plain language to involve the customer Avoiding data overload and using tools like Measure Quick and the TrueFlow Grid Following a process and getting paid for diagnostics, basic versus advanced retrofits Learning from mistakes and changing company culture This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, and Filtrete. Resources National Comfort Institute (NCI) website HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 12
50 min
Did You Actually Test Every Heat Strip - Short #311
In this short podcast episode, Bryan talks about electric heat and whether your service or maintenance procedure actually allows you to test every heat strip. In our climate, we use electric heat as auxiliary heat (as opposed to a furnace in a dual-fuel setup). There is also some information about maintenance procedures, blower interlocks and relays, and math to determine amperage. If you put the thermostat in heat and the blower runs, you only prove that the heat pump is heating; it doesn't tell you which electrical circuit is heating, or whether the auxiliary heat is producing heat at all. You can't assume that the last tech left you the correct kit with everything wired up and that it has been wired properly with the correct wire size. Electric heaters in heat pumps usually turn on with a W call from the thermostat or the defrost board. Sometimes, there is a high-voltage interlock with a relay that runs the blower with the electric heat but not the other way around. Older heat strips may also have heat sequencers, which follow a specific sequence and stage on or off over time. We test heat strips by forcing a call for heat, waiting as long as needed, measuring the amperage to make sure it matches the heat kit, making sure the blower comes on, and verifying that the call for heat ends as it's supposed to. Temperature rise may also be a useful measurement. If a similar procedure is part of your fall maintenance, let the customer know that there may be an odor, and you may clean dirty heat strips with compressed air or an electrical contact cleaner. The key takeaway is to make sure the amperage is correct and that the circuit's wiring and relays can safely carry the current. Don't assume that everything is correct when you work on a unit for the first time. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Copeland, and Santa Fe Dehumidifiers. Resources An Electric Heat Mistake (Tech Tip) Electric Heat & Blower Interlock (Tech Tip) Electric Heat Troubleshooting, Service, and Math Class (Video) Basics of Testing Electric Heat Kits w/ Bert (Video) Inside a Sequencer (Video) Sequencer Facts - They Aren't All the Same (Video) Relays, Sequencers, Transformers, and Bad Metaphors (Podcast) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 10
14 min
Uncovering the Root Causes of Commercial Refrigeration Failures
In this live stream, co-branded with Kalos, Bryan Orr sits down with Kalos refrigeration team members Christian Maitland and Alex Orr to talk about the realities of working on market refrigeration systems. The conversation starts with the rapid arrival of new equipment in grocery stores, especially transcritical CO2 racks, and why even well-trained techs are running into problems nobody has seen before. Because these are engineered, built-up systems rather than mass-produced units, the first real stress test often happens in the field, during installation and startup. The group digs into where those problems actually come from. Some are classic installation errors, like skipping nitrogen purges while brazing, leaving burrs in pipe, or forgetting that ACR copper plugs sit on the inside of the pipe. Others trace back to the manufacturer: sensors landed on the wrong terminals, swapped sensors that left a condenser fan unable to run, controllers that overheat and reset, and programming that was tested in a different climate than the one the equipment ends up in. With multiple manufacturers supplying the rack, controller, and condenser, nobody owns the interface between the pieces, so startup techs end up tuning parameters store by store. Bryan, Christian, and Alex also walk through the root cause process they rely on, which is essentially the scientific method: observe the complaint, form a hypothesis, test it, and then keep digging until you know why it happened and can confirm the fix on the next job. They discuss store dew point and airflow as the most common causes of iced-up and sweating cases, a humbling misdiagnosis involving a transducer and a redundant controller, and the pain of 19-week lead times and wrong parts arriving seven times in a row. The episode closes with practical advice for techs. Walk into every store and use your senses, check behind your install team, pull your vacuums, and document conversations with customers when expectations don't match the equipment specs. Christian encourages techs to share what they learn with peers, Alex reminds listeners that solving ridiculous problems is the job and a chance to be the hero, and Chad's late addition is a reminder that equipment should be designed for worst-case conditions rather than a design day. Topics Covered Transcritical CO2 coming to the U.S. market, and why it behaves differently above roughly 86°F Challenges of high ambient temperature and humidity in Florida, including limits of adiabatic cooling Controllers that overheat and reset, and how quickly a CO2 system can lose its charge when that happens Safety and mindset for techs moving from traditional DX to high-pressure CO2 systems Why built-up systems get their first real field test at installation and startup Clean piping practices: nitrogen purging, burrs, carbon buildup, and tiny orifices in ejectors and microchannel coils The pipe plug in the EPR story and other lessons from early grocery work Manufacturer errors caught at startup, including miswired harnesses and swapped sensors Interconnected controls from different manufacturers and the need for site-specific programming Setting customer expectations on case placement, shelving, and spec limits, and documenting those conversations Store dew point, dehumidifiers, and ceiling fans disrupting open-case air curtains Using building science tools like smoke pens and vane anemometers on refrigeration cases The root cause process: observe, hypothesize, test, find the real cause, and verify the fix A transducer misdiagnosis and why to rule out everything before ordering long-lead-time parts Parts lead times, wrong parts, and the hidden labor cost of learning new equipment alongside manufacturers Commissioning during live-store case swaps, and the gap in manufacturer training for new equipment What techs look for on a first walkthrough, plus startup checks like line sizing, case assembly, and pulling vacuums Gaps in tools, such as digital gauges built for transcritical systems Closing takeaways: share knowledge with peers, own the problem, and design equipment for worst-case conditions This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Copeland, Santa Fe Dehumidifiers, and TruTech Tools. Resources Matthew Taylor's Rack Refrigeration Series (YouTube playlist) Intro to CO2 w/ Don Gillis (podcast) CO2 Refrigeration Rack Overview (video) Ramping Your Team Up for CO2 (tech tip) How Do You Ramp Up Your Team to Effectively Service and Support CO2 Applications? (podcast) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 5
1 hr 1 min
Why and How to Test Heat Pump Defrost - Short #310
In this short podcast episode, Bryan covers why and how to test heat pump defrost during maintenance. Heat pumps need defrost because the outdoor coil absorbs heat in heating mode. Moisture collects and freezes on the coil during this process, and the rate at which it happens depends on the temperature and the amount of moisture in the outdoor air. Frost interferes with heat transfer and airflow and must be defrosted; the reversing valve shifts and auxiliary heat turns on. Before testing, identify the equipment brand and model, defrost control, and the defrost type (time & temperature or demand defrost); you may have a thermostat (open/close switch) or thermistor, and those have different operating and testing considerations. Some controls also allow you to accelerate timing. Forcing defrost according to the manufacturer's literature will let you discover whether the command sequence works, but it may not tell you whether the sensors are working. Common visual checks can also help you resolve defrost issues dealing with sensors, base pan heaters, and poor airflow. The key takeaway is to pay close attention to the defrost sequence, conditions, defrost logic, sensor type, and your own spidey senses when testing or diagnosing defrost. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, Filtrete, and the 2027 AHR Expo. Resources Learn Everything About Heat Pump Defrost (video) HVAC Defrost Troubleshooting | Timers, Sensors, and Boards (video) Heat Pump Defrost Cycle & Heat Strip Wiring Safety | HVAC Heating Season Preparation (video) How to Test Heat Pump Defrost and How Defrost Works (video) Upgrading Time & Temperature Defrost with Demand Defrost for Heat Pumps (tech tip) Heat Pump Defrost Troubleshooting Tips (tech tip) Coil Temp Sensors: Thermostats vs. Thermistors (tech tip) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Nov 3
11 min
Building a Business That Lasts: Why Culture Beats Strategy in HVACR w/ Tony Gonzalez
In this live stream episode, Bryan sits down with Tony Gonzalez, who has spent more than 25 years at Fieldpiece and now leads the company's training department. Tony started out packing boxes in the warehouse straight out of high school, and the two longtime industry veterans use his experience to dig into why culture matters so much when you are building a business that lasts. As Bryan puts it, culture may be talked about in HVACR, but it is true everywhere. Tony walks through TURTL, the five core values that anchor Fieldpiece's culture: Tribe, Upfront homework, Right stuff, Trust, and Lean. The missing "E" is intentional, since it reminds everyone to leave their ego at the door. He explains why values can't be purely aspirational, and how Fieldpiece keeps them alive through recognition, one-on-ones, and development reviews. Bryan shares how the same ideas show up at Kalos, including the phrase "professional pride, personal humility." The conversation then turns to leadership, which both guests agree is where culture is won or lost. They discuss why your culture is defined by the worst behavior you tolerate, why people stay at a company, and why curiosity should come before judgment. Tony describes the "bank account" of care that makes hard conversations productive, along with the Radical Candor idea of avoiding ruinous empathy. Bryan adds that clarity is kindness and that small problems should be dealt with before they become mountains. They close by looking at team building, using Bryan's flight crew analogy and the "right people on the bus" idea from Good to Great. Every role matters, leaders shouldn't only hire people like themselves, and snap judgments can make you overlook great talent. Bryan wraps up with a few of his leadership commitments, and Tony's final advice is to start documenting what matters to your organization, live it consistently, and give yourself grace on the leadership journey. Topics Covered: Tony's 25-year career at Fieldpiece, from warehouse to head of training The TURTL core values and why "Turtle" has no E Keeping core values visible through quarterly recognition, one-on-ones, and development reviews Leaders as culture carriers, and how culture shows up when things go wrong Defining culture as a social operating system and the worst behavior you tolerate Professional pride and personal humility, and leaders who celebrate their team's success Why people stay: growth, recognition, fair compensation, and connection to the mission Curiosity before judgment, root cause thinking, and celebrating failure Making "deposits" of care so difficult conversations go well Radical Candor, ruinous empathy, and clarity is kindness Handling bad news and building a safe environment for people to speak up Building a flight crew: hiring for attitude, valuing different strengths, and avoiding the horns effect The weakest link in the chain and treating every role as equally important Book recommendations: Good to Great, The Power of Company Culture by Chris Dyer, and Delivering Happiness by Tony Hsieh Bryan's leadership commitments: truth over comfort, open doors with no gatekeeping, and people over plans Key takeaway: leaders must live the culture, give yourself grace, and define your North Star. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, Copeland, Santa Fe Dehumidifiers, and TruTech Tools. Resources Good to Great by Jim Collins (book) The Power of Company Culture by Chris Dyer (book) Delivering Happiness by Tony Hsieh (book) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Oct 29
1 hr 5 min
Tight Enough to Fail - Short #309
In this short podcast episode, Bryan discusses electrical connections and whether tighter is better (or if a connection is tight enough to fail).  Torque is a turning effect; force is applied at a distance from the screw's center, and that force creates pressure at the connection. A quarter-turn doesn't tell us how much force we have applied. You may notice a tight screw with other signs of a poor connection, like discoloration; tightening the connection may not help. At a connection, we want very little resistance to current flow, and we get increased resistance and heat where we don't want it when connections are poor; according to Watt's law, when the resistance stays the same, doubling the current creates four times the heating power. However, temperature alone doesn't tell you the cause; thermal imaging is useful evidence, but we need operating conditions and current measurements, too.  The key takeaway is that tightening the connection as much as possible may do more harm than good; having a torque screwdriver and using it can help. When making new connections, use the torque screwdriver to torque to the proper specs right out of the gate. We must also consider wire sizing, wire placement, exposed conductors, and unacceptable double lugging. We must also be mindful of ferrules, including proper selection and crimping. Make all adjustments safely (without voltage), and if you do not have the manufacturer's data immediately available, look it up. Eventually, you will get an idea of what "good" looks like. Remember: tighter doesn't necessarily mean better. This episode contains embedded sponsor messages from Refrigeration Technologies, Carrier, NAVAC, Filtrete, and the 2027 AHR Expo. Resources Tightening Electrical Threaded Terminal Connections (tech tip) HVAC School calculators Submit a podcast question Learn about the GRIT Foundation Purchase your tickets or learn more about the 8th Annual HVACR Training Symposium at https://hvacrschool.com/symposium.
Oct 27
11 min
Load more