Episode 26: Thoracic Aortic Stenting

MP3

In this episode, Yogi and Sam delve into discussing thoracic aortic stenting.

Podcast 26 - Thoracic Aortic Stenting


The first endovascular thoracic aneurysm repair was performed by Dale in 1994 - with the use of custom designed graft with a combination go Gianturco Z-stents and polyester fabric. It was not till 2005 that a commercially available thoracic graft became available


The introduction of TEVAR has added further dimensions to open surgery by creating treatment options not previously available in treating aortic dissection, thoracic and thoracoabdominal aneurysm and traumatic injury.

  • In elderly patients, TEVAR has replaced open surgery and medical management for problems confined to the descending thoracic aorta 


Indications

  • Aneurysmal disease (>5.5cm) - true degenerative aneurysms vs. post dissection aneurysms vs. mycotic vs. pseudo aneurysms (Zone 2)
  • Complicated acute aortic syndromes
  • Blunt thoracic aortic injury 
  • Evolving techniques - management of dissection aneurysms in Zone 0/1


Approved Devices 

  • Gore TAG Conformable Thoracic Stent Graft
  • Medtronic Valiant Thoracic Stent Graft with Captivia Delivery System  
  • Cook Zenith Alpha
  • Endospan Nexus and Bolton
  • Terumo Aortic Relay Device  


Pre-operative Considerations

How do we do it?

  • General consideration - 
  • vascular access, iliac vessel diameters
  • For suitable iliac and femoral access vessels are required
  • Small diameters <7mm, existing calcification and vessel tortuosity have a profound impact on the procedure especially if present in combination 
  • The right femoral artery is typically favoured for device insertion, whereas the contralateral femoral artery is reserved for diagnostic imaging 
  • An ideal access vessel should be >7mm in diameter to accommodate a 22Fr sheath and >8mm for a 24 Fr sheath 
  • Alternate options - iliac conduits or endo-paving 
  • Landing zone 
  • General role >20mm of normal appearing aorta for an adequate seal zone - proximal and distal 
  • Longer seal zones is considered adequate for most cases, longer seal zones are preferable in angulated aortic segments to decrease the occurrence of Type 1 end-leaks and device migrations 
  • Anatomical boundaries include the left subclavian artery and the coeliac artery should be considered a
  • Proximal and distal aortic diameters 
  • Ishimaru’s Classification of Landing Zone 
  • Coverage of the left subclavian artery is generally well tolerated because of a rich collateral network - however routine exclusion should be discouraged because experimental and clinical evidence suggest that not all patients tolerate the occlusion safely 
  • The left subclavian artery is vital for perfusion of both the spinal cord and the brain via the left vertebral artery through the internal management and anterior intercostal branches 
  • When left subclavian coverage is considered, pre-operative CTA imaging should assess latency of the right vertebral artery, connections to the Basilian artery and the COW in order to identify patients that may not tolerate left SCA occlusion 
  • As we approach Zone 0,1 or sometimes in 2 supra-aortic debranching may be necessary 
  • Open CTS vs. CCA-CCA-SCA, CCA- SCA, chimney stents 
  • Imaging
  • CTA with fine slices
  • Sizing
  • Overzealous device sizing is associated with graft infolding, gutter formation and aortic neck degeneration due to excessive radial force \
  • Aortic diameters are measured with orthogonal reconstructions especially in areas of tortuosity and angulation 
  • Neck diameters between the proximal and distal sealing zones can vary
  • A 10 to 20% oversizing at the proximal landing zone is recommended; less for dissection 
  • Adjunctive Measures for Neuroprotection
  • Patients with long segment descending thoracic aortic coverage (>150mm), antecedent or concomitant abdominal aortic repair or bilateral internal iliac artery occlusions are at particularly high risk of spinal cord ischaemia 
  • Staging procedures 
  • Selective segmental artery coil embolisation 
  • Intra-operative monitorings - Near infra-red spectroscopy monitoring, transcranial doppler and EEG 
  • Identifying a threshold value with NIRS that correlates to cerebral ischaemia has been poor and it only gives information regarding the status of the frontal lobes
  • Spinal Drain 
  • Elevated Blood Pressure, MAP > 90mmHg —. Can increase to 100mmHg if neurologic deficits are noted 
  • Hb > 100
  • Oxygen supplementation 


Procedure

  • Percutaneous femoral artery access
  • Typically up the right for the graft 
  • Small access on the contralateral side for insertion of a diagnostic pigtail catheter 
  • After access is established, a stiff guide wire is advanced into the ascending aorta; curved 260cm Lunderquist Wire and positioned such that the apex of the curve rests against the aortic valve
  • The end of the wire should be marked and efforts made to ensure that the wire stays in this position 
  • Arch aortogram is performed via a pigtail catheter with a LAO of 30 to 60 degrees - the angle should be determined based on the pre-operative CTA
  • Air is then flushed from the system - ensure no air in the line; can be done by winding back into the pump or under water 
  • Induction of temporary apnoea necessary 
  • The endograft is introduced and advanced under fluoroscopic guidance 
  • Typically the endograft is advanced past the proximal landing zone and drawn back to eliminated stored energy 
  • Steady integrate pressure on the wire keeps the device positioned against the outer aortic wall for accurate deployment - stent grafts conform to the outer curvature of the thoracic aorta which can cause the graft to jump distally 
  • Forward pressure on the Lunderquist wire will help push the wire against the outer curvature to better approximate the true path of the stent graft during deployment 
  • The pressure can also help the apposition of the graft to the vessel wall, avoiding the “bird-beaking” effect
  • Acute angles in the descending thoracic aorta may render device tracking difficult  - put the graft at risk of Type 1 endoleak and bird bearing 
  • “Body flossing” - brachiofemoral access wires can help straighten the most angulated of vessels 
  • When more than one TEVAR device is required, the smallest diameter device should be deployed first; for large proximal aortic aneurysms, with distal thoracic aortic tortuosity deploying the distal endograft first is preferable as it stabilises the proximal endograft and improves deployment accuracy 
  • Proximal TEVAR deployments benefit from temporary reduction of mean arterial pressure which minimises the windsock effect and potential endograft migration 
  • Strategies - administration of vasodilators, adenosine induced cardiac asystole, rapid cardiac pacing, sustained Valsalva manoeuvre, IVC balloon occlusion
  • Ongoing aortic blood flow can become trapped in the deploying graft graft and displace the stent distally, in a phenomenon known as the “windsock” effect 
  • Graft molding is generally avoided in the setting of treatment for aortic dissection due to the risk of causing retrograde dissection - in aneurysmal disease, a non-compliant balloon can be used k
  • Completion angiogram


Complications

  • Mortality - early experience with first and second generation endografts in high risk individuals was associated with a high clearly mortality (9 to 12%); trials with third generation devices reported a 30 day mortality of 1 to 2.2% which is significantly lower than the 7% mortality associated with open surgical repair 
  • Stroke - 3 to 8% 
  • Presence of mobile atheroma, prior stroke, deployment of TEVAR proximal to the left CCA, air or plaque embolisation 
  • Paraplegia
  • Peripheral Vascular Complications - embolism, thrombosis and vascular trauma
  • Vascular access complications due to large bore sheaths placed in atherosclerotic arteries were relatively high in the early trials but lower in follow up trials (~6%) 
  • Aortic dissection
  • Aneurysm Sac Enlargement 
  • Stent graft migration or fracture
  • Late migration < 0.7 to 3.9% - can occur at either end; predisposing factors for device migration include excessive endograft oversizing, tortuous seal zone anatomy and aortic elongation 
  • Endoleak 


Reasons for Spinal Drain

  • Length of coverage > 20cm
  • Coverage in the region of the artery of Adamweikz
  • Previous infrarenal aortic repair 
  • Bilateral internal iliac artery atherosclerotic 
  • Coverage of the left subclavian artery 


However spinal drains are not without complications - that can arise during and/or after CSF drain insertion including catheter fracture, post dural puncture headache, neuroaxial haematoma, intracranial haemorrhage and meningitis 


Complications associated with left subclavian artery coverage during TEVAR

  • Stroke - students have demonstrated a high overall stroke rate and posterior circulation stroke with intentional coverage of the left subclavian artery compared with left subclavian artery revascularisation
  • Spinal cord ischaemia / long term - chronic symptoms (claudication)
  • Left upper extremity ischaemia


Reasons for left subclavian artery revascularisation 

  • Patent left arm arteriovenous shunt for dialysis 
  • Presence of a patent left internal mammary to coronary artery bypass graft 
  • Absent, atretic or occluded right vertebral artery 
  • A dominant left vertebral artery is present in > 60% of patients; intuitively these anatomic findings place patients at increased risk for posterior circulation infarction if covered 
  • Termination of the left vertebral artery into the posterior inferior cerebellar artery 
  • Prior infrarenal aortic operation with previously ligated lumbar and middle sacral arteries
  • Planned extensive (>20cm) coverage of the descending thoracic aorta
  • Hypogastric artery occlusion
  • Presence of early aneurysmal disease where future therapy involving the distal thoracic aorta may be necessary
  • Anomalous origin of the left vertebral artery from the aortic arch 


Anatomy of the Spinal Cord Circulation

  • Arterial supply
  • Anterior spinal artery which arises off the vertebral arteries
  • Prior to becoming the basilar artery, the vertebral arteries give off branches that become the anterior spinal artery which then passes down the anterior sulcus of the vertebral column
  • Posterior spinal arteries which arise off the posterior inferior cerebellar arteries and travel down caudally
  • Mid cervical cord receives blood supply via the segmental spinal arteries directly off the vertebral arteries
  • The lower cervical and upper thoracic cord receives blood supply via the radiculomedullary branches arising from the cervicothoracic trunk
  • Intercostal artery branches which give off segmental spinal arteries which supply the mid thoracic segment
  • The largest segmental spinal artery branch being the Artery of Adamkiewicz which arises from T8 to L2 
  • Branches of the internal iliac artery supply the lumbosacral segment 


This podcast uses Captivate for stats and dynamic audio and Captivate for stats and dynamic audio. What this means Episodes play from the podcast's own servers, unmodified. Not affiliated with Podbay.