Show notes
p, li {color: black;font-size: 18px;}
.has-drop-cap{font-size: 1.4em;}
Seth J Koenig, MD, Professor, Dept of Medicine and Cardiovascular and Thoracic Surgery; Professor of Medicine, Donald and Barbara Zucker SOM at Hofstra/Northwell; Director, Acute Lung Injury Center, Northwell Health; and Director, MICU at the Long Island Jewish Medical Center, presents on “Transesophageal Echocardiography in the Intensive Care Unit”.
Lecture Summary: TEE in the ICU – Seth Koenig
Summary by Dr. Keegan Tupchong
TEE in the ICU
* not dangerous * not hard * can be mastered by
non-cardiologists * data show that it helps clinical
decision-making
Reasons to learn TEE
* Anyone who is critically ill
probably deserves POCUS * TEE is used for all ECMO
cannulations at Long Island Jewish Medical Center * You will be left behind if you
don’t start learning TEE in fellowship * the same paradigm used to exist
for learning general POCUS as well as critical care TTE, and now everyone has
POCUS in their ICUs* Taking good care of a patient
means that at least you must know what is wrong * while it does not replace
clinical skills, TEE as an adjunct can give you the data needed to become a
better clinician* TEE is much less dangerous and
complicated than many other procedures required by ABIM: * airway management * CVCs, A-lines, PACs * ventilator management * There may not be an RCT showing
improved outcomes with TEE but … * this has yet to be shown for
ventilators, CT scans * “we hold these truths to be
self-evident” and assume that they benefit patients* Categorizing the shock state is
essential * “if you understand the shock
state then you know how to treat the shock state” * diagnosis of life-threatening
diseases saves lives * hemodynamic profiles change
constantly
TEE image acquisition:
* There are different types of gross
movements* vertical (advance/withdraw the
probe) * rotational (turning the
probe/beam plane) * anteroflexion/retroflexion * lateral flexion * multi beam * Beam path is the opposite of TTE
(from inside the chest pointed outwards)
Ten Reasons for Performing Hemodynamic Monitoring Using TEE (Vignon, et al,
ICM, 2017)
* TEE provides a unique window to
the heart and great vessels (e.g. dissection) * TEE provides unparalleled
information on the mechanism of circulatory failure (e.g. saddle PE, too
unstable to go to CT) * TEE allows reproducible and
sequential hemodynamic assessments * (e.g. slightly large RV but
normal SV (normal HR, VTI) may point towards vasodilatory rather than
obstructive shock (with old RV dysfunction))* TEE predicts fluid
responsiveness (better than any other cardiac output monitoring paradigm) * TEE is best suited to
quantitatively assess cardiac function (e.g. degree of severity of mitral
regurgitation) * TEE is key to identifying RV
dysfunction at the origin of low flow states (e.g. large ASD) * TEE is the only possibility to
monitor hemodynamic status in the context of the use of ECMO (e.g. cannula
placement) * TEE is quicker and easier to
initiate than other monitoring modalities, and less operator dependent than TTE
* Miniaturized TEE probes allow
prolonged hemodynamic monitoring * TEE potentially improves ICU
performance
Complications
* Risk of death = 0.0098%
(cardiology TEE) * Several large studies combined
show ~1 death in 30,